For over 35 years Fujitsu has been cooling and heating homes with ductless air conditioners and heat pumps. Today, Fujitsu makes some of the worlds most energy efficient ductless mini-splits with up to 27.2 SEER. ductless.ca carries Fujitsu's full line of Halcyon™ ductless mini-splits with 11 ENERGY STAR® qualified products for 2012.
Fujitsu Halcyon mini-splits are available in capacities from 9,000 to 48,000 Btu/h and up to eight indoor evaporator units can be connected to one outdoor condensing unit with Fujitsu's Hybrid Flex Inverter Technology. With seven year warranty for compressors, five years for parts and five years for labour (through ductless.ca), Fujitsu provides excellent support for their ductless mini-splits.

All Fujitsu Halcyon ductless mini-split air conditioners and heat pumps include long-life ion deodorizing filters. These decompose absorbed odors through oxidation and reduces the effects of ions generated by the ultra fine ceramic. In addition, apple catechin filters absorb dust and inhibit the growth of mold and microorganisms through static electricity.

By utilizing inverter circuits in many of their ductless units, Fujitsu is able to provide optimum power control and very efficient operation. The capacity of the system is dependent on the temperature of the area. As soon as the air conditioner is turned on, the inverter provides the power needed to rapidly cool the area. When maximum capacity is not needed, the energy usage of the system is decreased resulting in increased system efficiency.

The Halcyon's Energy Savings Program (ESP) system knows how to save you money even when you forget! If you leave the room without turning the unit off, ESP knows that you left and 20 minutes later the temperature is increased by 2.5 °C when cooling and reduced by 5 °C when heating. It returns to previous operating mode when you come back. This prevents wasteful operation to save energy without you having to think about it.

Fujitsu utilizes R-410A which is a zero ozone depleting refrigerant for all of their Halcyon ductless models in accordance with the Montreal Protocol.

Easier to use than most TV remotes, the included wireless controllers feature large and easy-to-read displays and lets you adjust fan speeds and output modes from anywhere in the room.

Fujitsu's Hybrid Flex Inverter System (HFI) is a combination of Variable Refrigerant Flow (VRF) and typical inverter multi-zone systems. Fujitsu utilized this system in their 9,000 to 24,000 RLFW and RLXFW single zone and 18,000 to 48,000 Btu RLXFZ multi zone systems. More information about Fujitsu's HFI system can be found by downloading the HFI brochure (PDF File).
| Model | 9RLS2 | 12RLS2 | 15RLS2 |
| Rated Cooling Capacity | 9,000 Btu/h [¾ tons] |
12,000 Btu/h [1 ton] |
14,500 Btu/h [1¼ tons] |
| Cooling Capacity (Min to Max) |
3,100 to 12,000 Btu/h |
3,100 to 13,600 Btu/h |
3,100 to 18,400 Btu/h |
| Heating Capacity (Min to Max) |
3,100 to 22,000 Btu/h |
3,100 to 22,100 Btu/h |
3,100 to 23,900 Btu/h |
| Dehumidification | 1.3 l/h | 1.8 l/h | 2.1 l/h |
| ENERGY STAR Qualified Unit | Yes | ||
| SEER | 27.2 | 25.0 | 21.5 |
| HSPF | 12.5 | 12.0 | 12.0 |
| Compressor Type | Inverter | ||
| Energy Saving Program (ESP) | Yes | ||
| Indoor Unit Noise (Quiet-Low-Medium-High) |
21-32-37-43 dB | 25-33-40-45 dB | |
| Outdoor Unit Noise | 48 dB | 49 dB | 51 dB |
| Rated Cooling Power Consumption | 560 W | 870 W | 1,210 W |
| Rated Heating Power Consumption | 800 W | 1,200 W | 1,350 W |
| Power Supply | 240 v, Split-Phase, 6 0Hz | ||
| Outdoor Temperatures for Cooling (Min to Max) |
-10 to 46 °C | ||
| Outdoor Temperatures for Heating (Min to Max) |
-21 to 24 °C | ||
| Model | 9R2 | 12R2 |
| Rated Cooling Capacity | 9,700 Btu/h [¾ tons] |
12,300 Btu/h [1 ton] |
| Rated Heating Capacity | 9,600 Btu/h [¾ tons] |
12,800 Btu/h [1 ton] |
| Dehumidification | 1.0 l/h | 1.5 l/h |
| ENERGY STAR Qualified Unit | No | |
| SEER | 13.0 | |
| HSPF | 8.2 | |
| Compressor Type | Single Speed | |
| Indoor Unit Noise (Quiet-Low-Medium-High) |
26-31-36-40 dB | 29-34-40-45 dB |
| Outdoor Unit Noise | 43 dB | 45 dB |
| Rated Cooling Power Consumption | 820 W | 1,070 W |
| Rated Heating Power Consumption | 690 W | 990 W |
| Power Supply | 120 v, Single Phase, 60 Hz | |
| Outdoor Temperatures for Cooling (Min to Max) |
0 to 46 °C | |
| Outdoor Temperatures for Heating (Min to Max) |
-8 to 24 °C | |
| Model | 9RLFW | 12RLFW | 18RLXFW | 24RLXFW | 30RLX |
| Rated Cooling Capacity | 9,000 Btu/h [¾ tons] |
12,000 Btu/h [1 ton] |
18,000 Btu/h [1½ tons] |
22,000 Btu/h [1¾ tons] |
30,000 Btu/h [2½ tons] |
| Cooling Capacity (Min to Max) |
1,700 to 10,900 Btu/h | 3,100 to 13,300 Btu/h | 7,000 to 23,000 Btu/h | 9,900 to 27,300 Btu/h | 9,900 to 32,400 Btu/h |
| Heating Capacity (Min to Max) |
1,700 to 15,000 Btu/h | 3,100 to 19,100 Btu/h | 7,000 to 29,000 Btu/h | 7,500 to 36,200 Btu/h | 8,000 to 37,500 Btu/h |
| Dehumidification | 1.3 l/h | 1.8 l/h | 2.8 1/h | 3.0 1/h | 4.5 1/h |
| ENERGY STAR Qualified Unit | Yes | No | |||
| SEER | 23.0 | 22.0 | 19.2 | 18.0 | 17.5 |
| HSPF | 11.0 | 10.0 | 9.5 | ||
| Compressor Type | Inverter (HFI) | Inverter | |||
| Indoor Unit Noise (Quiet-Low-Medium-High) |
25-29-33-37 dB | 25-30-36-40 dB | 28-33-37-43 dB | 33-37-42-49 dB | |
| Outdoor Unit Noise | 48 dB | 49 dB | 47 dB | 54 dB | |
| Rated Cooling Power Consumption | 650 W | 960 W | 1,350 W | 1,760 W | 3,000 W |
| Rated Heating Power Consumption | 890 W | 1,280 W | 1,800 W | 2,380 W | 2,990 W |
| Power Supply | 240 v, Split-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) |
-10 to 46 °C | -18 to 46 °C | |||
| Outdoor Temperatures for Heating (Min to Max) |
-15 to 24 °C | -18 to 24 °C | |||
| Model | 18CL | 24CL1 | 30CLX1 | 36CLX1 |
| Rated Cooling Capacity | 18,000 Btu/h [1½ tons] |
24,000 Btu/h [2 tons] |
30,800 Btu/h [2½ tons] |
33,000 Btu/h [2¾ tons] |
| Cooling Capacity (Min to Max) |
5,500 to 19,000 Btu/h |
3,100 to 25,000 Btu/h |
9,900 to 32,400 Btu/h |
9,900 to 34,100 Btu/h |
| Dehumidification | 2.8 l/h | 3.0 l/h | 4.6 l/h | 4.8 l/h |
| ENERGY STAR Qualified Unit | No | |||
| SEER | 19.0 | 17.5 | 16.5 | 15.5 |
| Compressor Type | Inverter | |||
| Indoor Unit Noise (Quiet-Low-Medium-High) |
25-32-38-44 dB | 33-37-42-48 dB | 33-37-42-49 dB | 33-37-42-50 dB |
| Outdoor Unit Noise | 50 dB | 56 dB | 54 dB | |
| Rated Cooling Power Consumption | 1,730 W | 2,400 W | 3,240 W | 3,880 W |
| Power Supply | 240 v, Split-Phase, 60 Hz | |||
| Outdoor Temperatures for Cooling (Min to Max) |
-10 to 46 °C | |||
| Model | 18RLXFZ | 24RLXFZ | 36RLXFZ | 36RLXFZ (18+18) | 48RLXFZ |
| Rated Cooling Capacity (Btu/h) |
18,000 Btu/h [1½ tons] |
22,000 Btu/h [1¾ tons] |
35,200 Btu/h [3 tons] |
31,600 Btu/h [2¾ tons] |
48,000 Btu/h [4 tons] |
| Rated Heating Capacity | 22,000 Btu/h | 24,000 Btu/h | 36,400 Btu/h | 35,800 Btu/h | 54,000 Btu/h |
| Connectable Unit Capacity | 14,000 to 21,000 Btu/h | 14,000 to 27,000 Btu/h | 27,000 to 39,000 Btu/h | 36,000 Btu/h | 39,000 to 62,000 Btu/h |
| Connectable Indoor Units | 2 | 2 to 3 | 3 to 4 | 2 | 2 to 8 |
| ENERGY STAR Qualified Unit | Yes (ASU9+ASU9) |
Yes (ASU9+ASU7+ASU7) |
No | ||
| SEER | 17.0 to 18.0 | 16.8 to 18.0 | 15.3 to 16.0 | 16.0 | 14.7 to 15.8 |
| HSPF | 9.2 to 9.3 | 9.3 to 9.5 | 9.1 to 9.4 | 9.3 to 9.5 | |
| Compressor Type | Inverter (HFI) | ||||
| Outdoor Unit Noise | 49 dB | 52 dB | 55 dB | 58 dB | |
| Rated Cooling Power Consumption | 1,440 W | 1,760 W | 4,000 W | 3,980 W | 5,520 W |
| Rated Heating Power Consumption | 1,870 W | 1,730 W | 3,000 W | 3,660 W | 5,020 W |
| Power Supply | 240 v, Split-Phase, 60 Hz | ||||
| Outdoor Temperatures for Cooling (Min to Max) |
-10 to 46 °C | 0 to 46 °C | 10 to 46 °C | -5 to 46 °C | |
| Outdoor Temperatures for Heating (Min to Max) |
-15 to 24 °C | -10 to 24 °C | -15 to 24 °C | ||