Server Room Cooling CalculatorDetermining the right air conditioner for your Server Room or Data CenterIn principle it's easy to calculate the size of air conditioning unit you need for your Server Room, just add together all the sources of heat and install an air conditioning unit that can remove that much. In practice it's rather more complicated. Providing sufficient cooling is essential to ensure reliable running of servers, routers, switches and other key equipment. Failure of the air conditioning can have serious consequences for the equipment itself and for your company. Early warning of problems and spare capacity in the cooling system are both highly desirable. Calculating Heat LoadThe amount of heat generated is known as the heat gain or heat load. Heat is measured in either British Thermal Units (BTU) or Kilowatts (KW). 1KW is equivalent to 3412BTUs. The heat load depends on a number of factors, by taking into account those that apply in your circumstances and adding them together a reasonably accurate measure of the total heat can be calculated. Factors include:
Floor Area of RoomThe amount of cooling required depends on the area of the room. To calculate the area in square metres: Room Area BTU = Length (m) x Width (m) x 337 Window Size and PositionIf, as is quite common, your Server Room has no windows, you can ignore this part of the calculation. If, however there are windows you need to take the size and orientation into account. South Window BTU = South Facing window Length (m) x Width (m) x 870 North Window BTU = North Facing windows Length (m) x Width (m) x 165 If there are no blinds on the windows multiply the result(s) by 1.5. Obviously if you are in the Southern Hemisphere you would swap the conversion factors as the heat on North facing windows is then greatest. Add together all the BTUs for the windows. Windows BTU = South Window(s) BTU + North Window(s) BTU OccupantsPurpose built Server Rooms don’t normally have people working in them, but if people do regularly work in your Server Room you will have to take that into account. The heat output is around 400 BTU per person. Total Occupant BTU = Number of occupants x 400 EquipmentClearly most heat in a Server Room is generated by the equipment. This is trickier to calculate that you might think. The wattage on equipment is the maximum power consumption rating, the actual power consumed may be less. However it is probably safer to overestimate the wattage than underestimate it. Add together all the wattages for Servers, Switches, Routers and multiply by 3.5. Equipment BTU = Total wattage for all equipment x 3.5 LightingTake the total wattage of the lighting and multiply by 4.25. Lighting BTU = Total wattage for all lighting x 4.25 Total Cooling RequiredAdd all the BTUs together. Total Heat Load = Room Area BTU + Windows BTU + Total Occupant BTU + Equipment BTU + Lighting BTU This is the amount of cooling required so you need one or more air conditioning units to handle that amount of heat. So what size of unit do I need?Small air conditioning units have a cooling capacity of between 5000 and 10000 BTUs. Larger units may be rated in tons of cooling. 1 ton of cooling is equivalent to 12 thousand BTUs. Ductless.ca has cooling solutions for both large data centers and small to medium size enterprise server rooms. Please call (416) 421-0200 or use our quote request form to see how we can satisfy your cooling needs today. << Return to the Ductless.ca's main server room cooling information page. |
ductless.ca NewsCertifications
|
East: (416) 421-0200 or West: (905) 602-6100 |
© 2008 ductless.ca Inc. |
We accept: |
| 419 Sutherland Dr., Toronto, ON, M4G 1K4 |